Gas detector OLCT 100, is designed for the detection of explosive or toxic gases as well as oxygen. It is now SIL2 certified by INERIS according to the EN 50402 standard, which corresponds to IEC/EN 61508 for gas detectors.
The detectors are available in both a pressure-proof version and a version with increased (ia) security, so that the OLCT 100 can be used for detecting gases in all ATEX zones.
Instruments with an infrared sensor can detect explosive gases under particularly difficult environmental conditions, where the simultaneous presence of chemical vapors could deactivate a catalyst cell.
The frontline IR sensor with a 3-year warranty provides excellent reliability and long sensor life.
The detector can be used regardless of the application and is available in several variants.
Additional information
Application Areas
ATEX zone 1, ATEX zone 2, Battery charging station, Biogas, Boiler room, Chemical storage, Cooling system, Engineering corridors, Laboratory, Oil/gas industry, Packing (slaughterhouse), Painting hall, Pump station, Server room, Sewage
ATEX / SIL2 gasdetector OLCT 100 – Oldham
Find further information further down the page
or call+45 42 42 50 70
Description
Gas detector OLCT 100 approved for ATEX / SIL2
Gas detector OLCT 100, is designed for the detection of explosive or toxic gases as well as oxygen. It is now SIL2 certified by INERIS according to the EN 50402 standard, which corresponds to IEC/EN 61508 for gas detectors.
The detectors are available in both a pressure-proof version and a version with increased (ia) security, so that the OLCT 100 can be used for detecting gases in all ATEX zones.
Instruments with an infrared sensor can detect explosive gases under particularly difficult environmental conditions, where the simultaneous presence of chemical vapors could deactivate a catalyst cell.
The frontline IR sensor with a 3-year warranty provides excellent reliability and long sensor life.
The detector can be used regardless of the application and is available in several variants.
Additional information
ATEX zone 1, ATEX zone 2, Battery charging station, Biogas, Boiler room, Chemical storage, Cooling system, Engineering corridors, Laboratory, Oil/gas industry, Packing (slaughterhouse), Painting hall, Pump station, Server room, Sewage
Oldham
Ammonia (NH3), Butane, carbon monoxide (CO), Freon, Hydrochloric acid (HCL), Hydrogen (H2), Hydrogen chloride (HCl), Hydrogen Cyanide (HCN), Hydrogen sulfide (H2S), LEL (explosive gases), Methane (CH4), Nitric oxide (NO), Oxygen (O2), Ozone (O3), Pentane, Phosphine (PH3), Sulfur Dioxide (SO2)
You may also like…
Light Industry and Laboratories OLC10 – Oldham
Analog and digital central MX32 – Oldham
Analog or digital central MX 43 – Oldham
Central approved for SIL2 and SIL3 MX 52/62 – Oldham