Continuous ground gas monitoring

Find further information further down the page or call +45 42 42 50 70.

Description

GasClam 2 – Continuous Ground Gas Detector

The GasClam 2 is perfect for continuous ground gas monitoring as it collects unmanned continuous ground gas concentration data as well as parameters that are known to control it – subsurface pressure, atmospheric pressure and water level.

Typical ground gas monitoring applications of the GasClam 2 include:

– Soil contamination and Remediation
– Decontamination
– Emergency Response
– Exploration

GasClam 2 – Features

Using the GasClam 2 for monitoring ground gas provides a hierarchy of financial benefits, these include:

– Reduced number of site visits by a field engineer
– Reducing the overall length of ground gas monitoring programmes as legislative data requirements can be met quicker
– The third, and largest savings are made by designing appropriate, rather than over-engineered, solutions based on complete and robust data

Ultimate Performance

– Supports and industry recognised best practice approach to ground-gas monitoring
– Battery powered deployment for over 3 months (depending on logging frequency)
– Reduces number of site visits

Ultimate Safety

– Demonstrates regulatory compliance and due diligence
– Optimised site management with insights from continuous ground gas monitoring

Ultimate Flexibility

– GasClam2 ground gas monitor fits in to standard 50mm/2” borehole
– Discrete installation

Additional information

Producer

Performance

Gas CO2**, CH4**, O2, CO*, H2S*, VOC*
Method / Type CO2, CH4: Infrared
O2, CO, H2S: Electrochemical
VOC: PID
Range CO2: 0-100 %
CO2: 0-5 %
CH4: 0-100%
CH4: 0-5%
O2: 0-25 %
CO: 0-2000 ppm
H2S: 0-100 ppm
VOC: 0-4000 ppm
Resolution CO2 0-100 %: 1 % above 50 % 0.5 % below 50 %
CO2 0-5 %: 0.05% above 2.5% 0.025 below 2.5 %
CH4 0-100 %: 1 % above 50 % 0.5 % below 50 %
CH4 0-5 %: 0.05 % above 2.5 % 0.025 below 2.5 %
O2: 0.1 %
CO, H2S, VOC: 1 ppm
Accuracy CO2 0-100 %, CO2 0-5 %, CH4 0-100 %, CH4 0-5 %: ± 2 % FSD
O2: ± 5 % of reading ± 1 digit
CO: < ± 3 ppm at 0 ± 5 % at 250 ppm ± 10 % full scale
H2S: < ± 1 ppm at 0 ± 2.5 % at 50 ppm
VOC: ± 5 % of reading ± 1 digit

Performance Dual CO/H2S

Method / Type Electrochemical
Range CO: 0 – 500 ppm
H2S: 0 – 200 ppm
Resolution 1 ppm
Accuracy CO: < ± 3 ppm at 0 ± 3 % at 250 ppm
H2S: < ± 1 ppm at 0 ± 2 % at 100 ppm

Environmental

Barometric Pressure Piezoelectric, 800 to 1250, 1 mBar
Borehole Pressure Piezoelectric, 800 to 1250, 1 mBar
Temperature Internal Chip, – 5 to + 50 °C or 22 to 122 ° F
Water Depth Piezoelectric, 0 – 25 m (Various available) 0.01 m

 

Power Options Internal: Option of Lithium primary cells or Duracell Alkaline D-Cells or Rechargeable battery pack
External: Accepts intrinsically safe external power supply for extended and/or rapid monitoring
Typical battery life (hourly sampling) Lithium primary cells – 3 months
Alkaline cells – 1 month
Rechargeable battery pack – 3 weeks
Weight and Dimensions 7.5 kg (16. lbs) Overall length: 90 cm (35.4 in) – Borehole tube length: 83 cm ( 32.6 in)
Head diameter: 11 cm (4.3 in) – Borehole tube diameter: 4.7 cm (1.85 in)
Protection IP68 rated (continuous submersion)
Operation Temp – 20 to 50 °C (- 4 to 122 °F)
Patents and Approvals European and World-wide Patented

EMC, ATEX 0105 X CE

II 2G Ex d ib [ib] IIB T4 Gb

IECEx Ex d ib [ib] llB T4 Gb

CSA C (US & Canadian Approvals)

Class 1, Zone 1 (A)Ex d id llB T4

European patent granted / Worldwide patent granted.
Exclusively sold and promoted by Ion Science Ltd.
GasClam 2® is a registered trademark of Intelisys Ltd T/A Salamander Group.
* Optional; ** Choice of 2 IR sensors, specify on order.

Download datasheet: here

Further supporting documentation for GasClam 2: here.

Related products:
Contact GasDetect

Fill out the form and we will get back to you as soon as possible.